- Home
- Thruster systems
- Spare parts
- Other
- SX50/140 thruster only
Other
SX50/140 thruster only
without controller
Item code: SM-147297
Sparepart for | Value |
---|---|
Main products > Thrusters > DC > SX | SX50/140-12V-50MM SXP50/140-12V-50MM |
-
Product announcement: SX50 Control box modifications
Marketing DocumentationEnglishpdf
SX50/140 thruster only
Guide to navigating spare parts
Below you will see the top-level assembly of spare part groupings available to you. If you desire a component within the presented assembly group, click on the name tag below the image to be directed to a detailed spare parts list for that assembly group. If no additional spare parts are available, it means that the current assembly group must be purchased as a whole due to service or installation requirements.
1 SX/YT 140-35
SX 140 Gearleg assembly
DIN 985 - M8x1,25
DIN 125 - A 8,4
ISO 8734 - 4 x 20 - A
SX140 Motor assembly 1,8
2 Fastener SX140 50mm
Gasket
Gasket
Washer
Washer
Washer
Nut
Pin bolt
Nut
Washer
Gasket
Gasket
Lock nut
Conductor XS mount
Lock nut
Sleeve
3 SX35/50 Side Covers Replacement Kit
Cover SX 1 B
Cover SX
Selftaper DIN912 4,8 x 25 A4
Selftaper DIN912 4,8 x 16 A4
Disclaimer
Sleipner warranties the original spare parts supplied only. The installer alone has responsibility for the installation of the spare parts. Do not attempt to fit replacement parts unless you are competent. If the spare part is fitted incorrectly, Sleipner Group will not be liable for any damage resulting.
The information given in the document was correct at the time it was published. However, Sleipner Group cannot accept liability for any inaccuracies or omissions it may contain. Continuous product improvement may change the product specifications without notice. Consequently, Sleipner Group cannot accept liability for any possible differences between product and document.
-
Not necessarily. These systems typically come with a Battery Management System (BMS) that will disconnect the thruster in case of any issue with the battery (for instance, if the thruster draws more current than the BMS allows). Just imagine a sudden cut-out in the middle of a maneuver without any pre-warning.
At Sleipner, we recommend a solution with a simple, separate battery and without a disconnect BMS system (such as the lead acid bank frequently used for starting or similar). The helmsman will then be warned when the battery is getting low and feel that the thrusters are gradually losing power, which is significantly better than losing your thrusters without any pre-warning.
Disclaimer: Ensure battery/energy source is installed according to CE/ISO current rules and regulations and by licensed electricians.
-
Yes, you can, but not without taking some precautions. Sleipner produces two product lines of thrusters that will work well with high-capacity batteries and one product line which should be used with caution in combination with LiFePO4, Lithium, Li-ion, or similar batteries, which may be capable of delivering higher voltage under load than traditional batteries (such as lead-acid, AGM, gel or similar).
- All Sleipner proportional thrusters will work well with Li-ion or LiFePO4 batteries, as the included PPC unit will control the output voltage to a safe level for the thruster. Make sure, though, that you actually get a good battery intended for maritime use. NB - make sure you have the latest embedded software installed.
- All Sleipner eVision thrusters have built-in functionality to limit the maximum voltage delivered to the thruster. Again, make sure your battery is intended for maritime use.
- Traditional DC on/off thrusters may be damaged or have a reduced life expectancy if operated at voltage levels outside their specifications.
Disclaimer: Ensure battery/energy source is installed according to CE/ISO current rules and regulations and by licensed electricians.
- All Sleipner proportional thrusters will work well with Li-ion or LiFePO4 batteries, as the included PPC unit will control the output voltage to a safe level for the thruster. Make sure, though, that you actually get a good battery intended for maritime use. NB - make sure you have the latest embedded software installed.
-
Yes. Most engineers would tell you that it is not ideal for connecting the bow thrusters to a service bank protected by a Battery Management System. Thrusters are heavy consumers, and they may create sudden peaks in current draw, which again may cause the BMS to disconnect the batteries if the thruster draws more current than allowed. If this happens in the middle of a maneuver, you would be left without thrusters and may lose control of the boat.
Hence, Sleipner recommends that the thrusters be connected to a separate battery bank (that is not lithium) without a Battery Management System that can disconnect the batteries (and consequently the thrusters).
Disclaimer: Ensure battery/energy source is installed according to CE/ISO current rules and regulations and by licensed electricians.
-
A Lithium or Li-ion battery may maintain a significantly higher voltage and higher current under load than a lead-acid, gel or AGM battery. This will provide significantly more power to the thruster motor and give some undesired side effects:
- The propeller will rotate significantly faster and with higher power than what they are designed for, increasing the risk of cavitation and following damages in the tunnel and at the thruster.
- The thruster risks overheating and will have shorter run times. This can cause the thruster to stop in the middle of a maneuver.
- Over time, the thruster may be damaged and you may have a reduced life expectancy.
Sleipners speed controlled thrusters will not be impacted by Lithium, Li-ion or similar battery times providing a steady high voltage.
Disclaimer: Ensure battery/energy source is installed according to CE/ISO current rules and regulations and by licensed electricians.
-
This is a unique patented Sleipner safety feature supplied with all standard (on/off) DC electric Sleipner thrusters. The IPC functionality provides two unique features:
1) It will detect "flapping" of the solenoid (typically caused by badly charged batteries that are subject to a huge current draw and voltage drop when the thruster motor is engaged), and will stop trying to run the thruster, preventing excess solenoid contact tip wear and dramatically reducing the risk for a weld-in situation of the solenoid. A 'weld in' (run away) situation is when a thruster continues operating without a signal from the operator at the control panel.
2) Even if the solenoid has a weld-in situation, which even with the IPC prevention actions is still possible, as all mechanical switches can weld-in at a point, the unique IPC function will STOP THE THRUSTER, without active action by the operator. This will give the operator time to locate and Select OFF on the thruster system Isolation/Main Switch.
-
Sleipner recommends that the thrusters are connected to a battery bank that is not protected by a Battery Management System (BMS). Typically this means lead-acid, AGM, gel, or similar kinds of batteries. This is important because thrusters draw a lot of currents quickly, and the high amp draw may lead the BMS system to think that there is an issue with the system and consequently disconnect the batteries from the circuit, in which case you would lose maneuverability.
If you have Lithium batteries powering your thrusters, the best advice we can give you is to check the actual voltage measured on the thrusters during operation. Sleipner thrusters are designed to operate within a specific voltage range, and as long as you are within these boundaries, it doesn’t matter for the thruster if the current is delivered by this or that battery pack.
It may also be a very good idea to check the actual current drawn from the battery during full power at the thruster to see that you are not at the limit for the BMS to avoid sudden loss of maneuverability if the BMS disconnects the battery.
With installations where the battery pack is far from the thruster, the higher voltage delivered by LiFePO4 or similar batteries might not be a problem as you will experience a voltage drop through the long cables.
Always make sure you measure your voltage on the thruster to avoid the risk of early thruster wear.
As battery tehcnology is changing rapidly, we always recommend consulting a professional battery supplier.
Disclaimer: Ensure battery/energy source is installed according to CE/ISO current rules and regulations and by licensed electricians.
-
A legacy that commits
We’ve lived and worked with the unruly sea for a hundred years. That’s why we develop important features that enables a boat to handle the sea better – that enable you to enjoy your boat, at anchor and at full speed. That is why you wanted a boat, isn’t it?
-
Beautiful engineering
The technology in our solutions is world-class. We know, because we’ve developed it ourselves, just as we manufacture every solution, and follow them until their fixed to a hull, ourselves. This meticulous attention to detail is why your day out always will be better with a Sleipner aboard.
-
Worldwide service
We take pride in our solutions’ function throughout their lifespan. So, we never really let them out of sight, even when they’ve left for distant shores. Our global network is there to ensure continuous optimal function. You know what you get with a Sleipner, today and tomorrow.